Grounding, Pressure ratings at high temperatures, Step 5 grounding – Emerson MICRO MOTION F-SERIES SENSOR User Manual

Page 21

Advertising
background image

Sensor Installation: F-Series

19

Grounding

Step 5

Grounding

The sensor can be grounded via the piping if the joints in the pipeline are ground-bonded. If the sensor is not
grounded via the piping, connect a ground wire to the internal or external grounding screw, which is located
on the core processor housing or junction box.

Improper grounding can cause measurement error. Ground the flowmeter to earth, or follow ground
network requirements for the facility.

If national standards are not in effect, follow these guidelines to ground the sensor:

• Use copper wire, 14 AWG (2,0 mm²) or larger wire size for grounding.

• Keep all ground leads as short as possible, less than 1 ohm impedance.

• Connect ground leads directly to earth, or follow plant standards.

Pressure Ratings at High Temperatures

Table 3 shows the pressure ratings for F-Series sensors at high temperatures.

1. Pressure rating limited by flange (for 316 sensor tubes).
2. Pressure rating limited by sensor tube for sensor type F025S, F050S, F050A, F050C.
3. Pressure rating limited by flange for sensor type F025A, F025C, F025P, F050P.
4. Pressure rating limited by flange (for C-22 Alloy sensor tubes).

Table 3

F-Series pressure ratings at high temperatures

EN-1092 flange

Pressure rating (bar)

Note

PN

Type

Facing

Description

ASTM

material

50°C 100°C 150°C 200°C 250°C 300°C 350°C 400°C 427°C

40

11

weld
neck

B1 & D

Flange, EN

1092-1 PN40

Forms B1 & D

(316)

316

40.0

40.0

36.3

33.7

31.8

29.7

28.5

27.4

26.9

1

100

11

weld
neck

B2 & D

Flange, EN

1092-1 PN100

Form B2 & D

(316)

316

100.0 100.0

90.9

84.2

79.5

74.2

71.4

68.5

67.3

1

100/

160

11

weld
neck

B2

Flange, EN

1092-1

PN100/160

Form B2 (316)

316

100.0 100.0

90.9

84.2

79.5

74.2

71.4

68.5

67.3

2

160.0 160.0 145.5 134.8 127.2 118.8 114.2 109.7 107.8

3

40

32/02

lap

joint

B1

Flange, EN

1092-1 PN40

Form B1(lap

joint)

C-22 collar/

304 flange

40.0

34.4

30.8

28.0

26.0

24.1

23.0

22.0

21.4

4

Advertising