35 operation – HONDA EM7000is User Manual

Page 37

Advertising
background image

35

OPERATION

AC Receptacle Selection

The generator has separate main power producing circuits. These two
circuits supply power to different receptacles shown when the voltage
selector switch is in the 120/240 V position.

When two or more receptacles are used, prevent overloading by
dividing the load between the two power circuits.

The chart below shows the rated load in amperes that can be
connected to each receptacle to balance the generator when the 120/
240 V locking plug receptacle is used for 120 V.
The total rated ampere draw is:

Receptacles powered
by each main circuit

1, 3 and 4

2 and 5

Power distribution

1

3

4=18.8A rated.

2

5=18.8A rated.

Receptacles powered
by each main circuit

1, 3 and 4

2 and 5

Power distribution

1

3

4=22.9A rated.

2

5=22.9A rated.

Main power circuit

Main Circuit I

Main Circuit II

Main power circuit

Main Circuit I

Main Circuit II

37.5 A
45.8 A

EM5000is

EM7000is

EM5000is:
EM7000is: