9

CONNECTING TO OMNILT
Connect the "Yellow" and "Green" wires from the touchscreen to the "YEL" and "GRN"
terminals under the section marked "CONSOLE" on the controller, respectively. Connect the
"Red" and "Black" wires from the touchscreen to the "12V" and "GND" terminals under the
section marked "AUX" on the controller, respectively.

A maximum combination of 4 touchscreens and consoles can be used with OmniLT.

NOTE: Do not exceed the maximum current limitation of the controller. If more than 1
touchscreen is used, the additional touchscreens must be powered from an external power
supply or HAI Touchscreen Hub.

THE EXTERNAL POWER SUPPLY MUST BE GROUNDED TO THE CONTROLLER
EARTH GROUND TO AVOID DAMAGE TO THE TOUCHSCREEN.