69-1074

2

T8624D CHRONOTHERM

®

IV DELUXE ZONE MULTISTAGE THERMOSTAT

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

Fig. 1. Typical location of thermostat.

Fig. 2. Mounting the wallplate.

·

Use a pencil to mark the mounting holes. See Fig. 2.

»

Remove the wallplate from the wall and drill two
3/16 inch holes in the wall (if drywall) as marked.
For firmer material such as plaster, drill two
7/32 inch holes. Gently tap anchors (provided) into
the drilled holes until flush with the wall.

¿

Position the wallplate over the holes, pulling wires
through the wiring opening.

´

Loosely insert the mounting screws into the holes.

²

Tighten mounting screws.

WIRING

All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 and 4 for typical hookups. A
letter code is located near each terminal for identification.

CAUTION

Disconnect power before wiring to prevent
electrical shock or equipment damage.

³

Loosen the terminal screws on the wallplate and
connect the system wires. See Fig. 5.

IMPORTANT

Use 18 gauge, color-coded thermostat cable for
proper wiring.

·

Securely tighten each terminal screw.

»

Push excess wire back into the hole.

¿

Plug the hole with nonflammable insulation to
prevent drafts from affecting the thermostat.

WIRES
THROUGH WALL

WALL

MOUNTING
HOLES

M15044

MOUNTING
SCREWS

WALL
ANCHORS
(2)