Halsey Taylor OVL-II SR-Q User Manual

Page 5

Advertising
background image

5

OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F

97793C - 10/01

Legend

Item

Description

A

3/8” O.D. Tube - Water Outlet Connection

B

3/8” O.D. Tube - Water Inlet Connection

C

1-1/4” O.D. Tube - Waste Tube - Not provided

D

Electrical Inlet on Chiller

Figure 8 – OVL-II SER-Q/OVL-II ESR-Q Rough-In Dimensions

5. Install the frame assembly squarely in wall opening

with frame upright support edges flush with the

finished wall face. Secure the frame to the wall

through holes with (12) 5/16” bolts or screws (not

provided). Tighten securely.
NOTE: Be sure that frame is squared in location. Do

not use less than required screw quantity

and size.

6. Attach the chiller shelf support rods to the right side

of the frame uprights at the second set of holes

counting from the bottom and to the shelf at the (2)

side holes. Line up the other shelf holes with the

frame bottom holes and fasten the assembly to the

wall opening using appropriately sized screws or

bolts and nuts (not provided).