Page 10

SKU 98982

For technical questions, please call 1-800-444-3353.

Press “ZERO/TARE” to change the

2.

brightness. The maximum is 5.
Press “FUNC” after selecting the

3.

brightness to switch to the manual

tare setting mode.
The screen will briefly display PStAtE

4.

and then display 0000.00 Enter the

tare weight in kg using the “UNIT”

button to select the digit and the

“ZERO/TARE” button to change the

digit. Once the tare is selected, press

the “ADD” button to return to normal

weighing mode.

Calibration:

note: Calibration is a precise procedure.

If done improperly, it can cause the

scale to become inaccurate. If you

are not comfortable doing the calibra-

tion yourself, a qualified technician

should calibrate the scale.
Turn the scale off. Calibration must

1.

be started when first turning on the

scale.
Connect the scale to an 120 V~ re-

2.

ceptacle and remove all weight from

the scale.
Turn on the Scale. Quickly press

3.

“ZERO/TARE”, “UNIT”, then “ZERO/

TARE” after the scale displays

012345, but before the scale is ready

to weigh. The scale will enter calibra-

tion mode and display the original

maximum capacity value and the

division.

These are factory settings

and should not be altered. Press

“Add” to continue.
The display will now read “-CAL-”

4.

first, then “0150.00”. Now input the

calibration weight, in kg. Leave the

platform empty.
Press “UNIT“ to select the digit you

5.

wish to alter. The selected digit flash-

es. Press “ZERO/TARE“ to change

the desired digit. Press “ADD” to fin-

ish entering the calibration weight.
Wait for the Indicator to display

6.

“0.00”, this may require a minute or

two. Then, put the calibration weight

on the Platform.
If the value is the same as the cali-

7.

bration weight, press “HOLD”. If not,

press “ZERO/TARE”, then “HOLD“ to

exit calibration mode, turn off scale

and retry calibration.

Error Information:

“Ad_Err” =

1.

Can not receive the

weight signal from the Sensor (8).
“------” =

2.

Zero position is too high or

the value is too high.
“___” =

3.

Zero position is too low or

the value is too low.
“Lo_bat” =

4.

The battery voltage is too

low.
“---OL---” =

5.

Overload.

“SEtErr ----” =

6.

The data is not cor-

rect.

Advertising