D. junction box installation – Heat & Glo Fireplace Soho24B 2137-900 User Manual

Page 31

Advertising
background image

31

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

IGNITION

MODULE

(3V)

VALVE

NEUTRAL

GROUND

LOW VOLTAGE

SEE NOTE 1

REMOTE

CONTROL

HOT

PLUG-IN

REMOTE

JUMPER WIRE

ORG

GR

N

BRN

BRN

RED

BLK

INTERMITTENT

PILOT IGNITOR

ORG

WHT

IGNITION MODULE 3 VAC

TRANSFORMER

VALVE

3 VAC

THERMOSTAT

WIRE

ASSEMBLY

BLACK WIRE CAN BE

PLUGGED INTO ANY

OF #1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF#1 - #5 LOCATIONS

ON THE NEUTRAL SIDE

GROUND TO

FIREPLACE

CHASSIS*

Figure 10.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram - Standard Method. Note: Appliance will not operate unless properly grounded.

D. Junction Box Installation

If the box is being wired from the OUTSIDE of the
appliance:

• Remove the cover plate located on the outer shell

- right side (see Figure 10.2).

• Install the supplied Romex™ connector in the cover

plate.

• Feed the necessary length of wire through the

connector.

• Make all necessary wire connections and reattach

the cover plate to the outer shell.

If the box is being wired from the INSIDE of the
appliance:

• Remove the screw attaching the junction box/

receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell (see
Figure 10.2).

• Pull the electrical wires from outside the appliance

through this opening into the valve compartment.

• Feed the necessary length of wire through the connector.

• Make all necessary wire connections to the junction box/

receptacle and reassemble the junction box/receptacle to the
outer shell.

WHT

WHT

BLK

BLK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Cover Plate
outside firebox

Romex
Connector

Figure 10.2 Junction Box Detail

NOTE: Do NOT wire