SERIES 90 MODUTROL IV™ MOTORS

9

63-2190—3

Fig. 6. Typical Series 90 wiring.

Fig. 7. Wiring for potentiometer control.

Fig. 8. Auxiliary switch schematic.

Fig. 9. Stroke adjustment setup for

non-spring return models.

Auxiliary Switches

Adjustable cams actuate the auxiliary switches. These cams

can be set to actuate the switches at any angle within the

stroke of the motor. Select switch differential of 1° or 10°.

Motors with factory-added auxiliary switches are shipped in

the closed position (fully counterclockwise, as viewed from the

power end). Auxiliary cam default actuates the switches 30°

from full open with a 1° differential. With the motor in the

closed (fully counterclockwise) position, the auxiliary switch

breaks contacts R-B. See Fig. 8 (or the auxiliary switch

Instruction Sheet) for auxiliary switch wiring.

NOTE: Auxiliary switches can only be added to motors that

include auxiliary switch cams. (These cams cannot

be field-added.)

TRADELINE motors are shipped with auxiliary switch cams

that permit acceptance of 220736A,B Internal Auxiliary Switch

Kits. Refer to form 63-2228 for 220736A,B installation

instructions.

L1

(HOT)

L2

1

1

2

R

W

B

R

W

B

T1

T2

TRANSFORMER

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

OVERLOAD PROTECTION AS REQUIRED.

TRANSFORMER MAY BE INTERNAL OR EXTERNAL

M770A

SERIES 90

CONTROLLER

MOTOR

L1

(HOT)

L2

1

1

2

R

W

B

R

W

B

T1

T2

TRANSFORMER

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

OVERLOAD PROTECTION AS REQUIRED.

TRANSFORMER MAY BE INTERNAL OR EXTERNAL

M18974

135 Ohm

Potentiometer

MOTOR

BLUE LEAD

YELLOW LEAD

RED LEAD

USE NEC CLASS 1 WIRING UNLESS POWER SUPPLY

MEETS CLASS 2 REQUIREMENTS. TAPE UNUSED LEADS.

ENSURE THE CURRENT DRAW OF THE EXTERNAL CIRCUIT

IS LESS THAN SWITCH CONTACT RATING.

ON TWO-SWITCH MOTORS, SECOND SWITCH HAS BLACK

LEADS WITH BLUE, YELLOW, AND RED TRACERS.

SOME AUXILIARY SWITCH ASSEMBLIES INCLUDE ONLY

RED AND YELLOW LEADS. SOME OTHERS DO NOT INCLUDE

THE YELLOW LEAD.

M17099

1

1

1

2

2

2

2

3

3

OUTER STROKE

ADJUST CAM

OUTER STROKE ADJUST CAM IS ONLY

PRESENT ON HIGH TORQUE MOTORS.

M17100

POWER END

OF MOTOR

INNER STROKE

ADJUST CAM

AUXILIARY

SWITCH CAMS

MOVE SCREWDRIVER AT

TOP ONLY TO ADJUST CAM.

1/8 INCH

STRAIGHT-BLADE

SCREWDRIVER

CAM

1

2

1

2

TORQUE

NO. OF

CAMS

CAM

COLOR

HIGH

LOW

2

1

YELLOW

BROWN

Advertising