T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS

5

69-1410—2

Temperature Settings

Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owner’s Guide, form number 69-0940, for complete
instructions on changing the program.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings do not require changing. Review the
factory settings in Table 2 and, if no changes
are necessary, go to the Installer Self-Test
section.

The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, system changeover and outdoor
temperature display. Installer Setup numbers are listed in
Table 3. The table includes all the configuration options
and the factory-settings for the T8601.

A combination of key presses are required to use the
Installer Setup feature:
— To enter the installer setup, press and hold the

information i key with the increase ! and
decrease " keys until the first number is displayed.
All display segments appear for approximately three
seconds before the number is displayed. See Fig. 10
and 11.

— To advance to the next Installer Setup, press the

Time

key.

— To change a setting, use the increase ! or

decrease " key.

— To scroll the Installer Setup numbers backward, press

the Time

key.

— To exit the Installer Setup, press Run Program.

Fig. 10. Display of all LCD segments.

Fig. 11. Display of Installer Setup

number and setting.

CAUTION

Electric Heat System Configuration Hazard.
Can cause equipment damage.
Configure electric heat system to 1 in Installer
Setup number 2 to prevent system running
without the fan.

IMPORTANT

Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 is not
displayed. Review Table 3 factory settings and
mark any desired changes in the Actual
Settings column. When Installer Setup is
complete, review the settings to confirm that
they match the system.

Table 2. Default Program Settings.

Period

Time

Heat Setpoint

Cool

Setpoint

Fan

Setting

Wake

6:00 AM

70°F (21°C)

78°F

(25.5°F)

Auto

Leave

8:00 AM 62°F (16.5°C)

85°F

(29.5°F)

Auto

Return

6:00 PM

70°F (21°C)

78°F

(25.5°F)

Auto

Sleep

10:00 PM 62°F (16.5°C) 82°F (28°F)

Auto

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

FFan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht

M14618