Henny Penny 500 User Manual

Henny Penny Fryers

Advertising
background image

Model 500/600

3-1. OPERATING CONTROLS

Refer to Figure 1.

Fig.

Item

Description

Function

No.

No.

1

1

Digital Display

Shows all the functions of the Cook Cycle, program modes,
diagnostic modes, and alarms

1

2

Used to start and stop Cook Cycles

1

3

Lights when the shortening temperature is 5

° F (3° C) below

to 15

° F (9° C) above the cooking temperature, signaling the

operator that the shortening temperature IS at the proper
temperature for cooking product

1

4

Product Select

Used to select the product for cooking and the LED above

Buttons

the selected product is lit; to start Cook Cycles with them; see
section 2, Special Program Mode item SP-10

1

5

Menu Card

The name of the food product associated with each product

Window

selection button; the menu card strip is located behind the decal

1

6

Press to access program modes; once in the program mode, it
is used to advance to the next setting;

1

7

COOK/PUMP Switch

A 3-way switch with a center OFF position; turn the switch

to the COOK position to operate the fryer; turn the switch to
the PUMP position to operate the filter pump; certain conditions
must be met before operating the filter pump; these conditions are
covered later in the Filtering section of the fryer manual

1

8 & 9

Used to adjust the value of the currently displayed setting in
the Program modes

SECTION 3. OPERATING INSTRUCTIONS

1207

3-1

Advertising