3-10. CHANGING THE

FILTER ENVELOPE
(Continued)

10. Fold the corners in and then double fold the open end.

11. Clamp the envelope in place with the sealer bar.

12. Screw on the suction standpipe assembly.

13. Place complete filter screen assembly back into filter drain pan

and slide pan back into place beneath the fryer.

14. Connect the filter union by hand. Do not use a wrench to tighten.

15. Slide the condensation drain pan back into place. The fryer is

now ready to operate.