Henny Penny 500 User Manual

Page 15

Advertising
background image

Model 500/600

1207

3-15

3-6. REGULAR MAINTENANCE

SCHEDULE

Procedure

Frequency

Filtering of shortening

Every 3 to 6 frying cycles

Filter pump problem prevention

As required

Changing of shortening

As required

Changing the filter envelope

As required

Cleaning the frypot

Before changing the shortening

Cleaning the deadweight valve

Daily

Night closing procedures

Daily

Check optional rinse hose

Weekly

for deterioration

Reversing the lid gasket

Quarterly

Lid lubrication

Quarterly

Limit stop adjustment

Quarterly

Check tightness of spreader bars

Quarterly

Clean safety relief valve

Annually

The filter pump motor is equipped with a manual reset button,
located on the rear of the motor, in case the motor overheats. Wait
about 5 minutes before attempting to reset this protective device to
allow motor to cool. The filter motor is on the rear of the fryer. It
takes some effort to push the reset, and a screwdriver can be used to
help reset the button.

Electric fryers with serial numbers of HB013JB & below, and gas
fryers with serial numbers of GA085JB & below, can push the reset
button, by removing the access panel on the left side panel of the unit.

To prevent burns caused by splashing shortening, turn
the unit’s main power switch to the OFF position before
resetting the filter pump motor’s manual reset protection
device.

3-7. FILTER PUMP

MOTOR
PROTECTOR-
MANUAL RESET

As in all food service equipment, the Henny Penny pressure fryer does
require care and proper maintenance. The table below provides a
summary of scheduled maintenance.

Advertising