1. Connect the female quick disconnect, that is attached to

the hose in the rear of the fryer, to the correct male quick
disconnect at the wall. Once attached, the hose can
remain connected unless the fryer is moved. Figure 1.

In order for the system to work properly, attach the hose

to the shortening return line only.

2. Open the drain valve and drop the shortening from the

frypot, into the drain pan.

3. Once all shortening is gone from frypot, turn the red

handle counterclockwise, into the down position and
hold. Figure 2.

4. While holding the handle down, turn the COOK/PUMP

switch to the PUMP position. Shortening is now pumped
from the drain pan.

5. Once all the shortening is out of the drain pan, turn the

COOK/PUMP switch to the OFF position.

6. Turn red handle back to original position.

7. Frypot is now ready for fresh shortening.

3-13. OPERATING INSTRUC-

TIONS FOR OPTIONAL
DIRECT-CONNECT
SHORTENING SYSTEM

Figure 2

Figure 1