Manual Alarm Action Setup (2)

< Figure 22 > Manual Alarm Action Setup (2) screen.

This screen allows you to set the actions the operator can take, what

relays will be activated and what cameras are associated with other

cameras.

There are three possible settings. Timed: The alarm will

“time out” at the designated time (Hold Time) unless the operator

clears it earlier.

Latched : The alarm remains active until the operator acknowledges

it. Trans (Transparent): The alarms are not latched and cannot be

cleared by the operator.

There are four possible relay settings. 1 or 2: Sets either

internal relay 1 or 2 to be activated by an alarm. 1&2: Sets both

internal relays 1 and 2 to be activated by an alarm. Off: Neither

internal relay will be activated by an alarm.

• Action :

• Relay :

• Alarm Link : This selects whether the alarm action will be linked or

not. It can be set to Off or any of the 9 alarm actions. All alarm

actions take priority over manual alarm actions.