Km-320mwh – Hoshizaki KM-320MAH User Manual

Page 27

Advertising
background image

27

2. KM-320MWH

Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold

should be used for reference only.

We reserve the right to make changes in specifications and design without prior notice.

PERFORMANCE DATA NO. 05A014

ISSUED: 11/29/05

ITEM: HOSHIZAKI MODULAR CRESCENT CUBER
MODEL: KM-320MWH

70/21

352

160

348

158

324

147

80/27

349

158

342

155

309

140

90/32

348

158

337

153

308

140

lbs./day kg./day

100/38

337

153

330

150

281

127

70/21
80/27
90/32

watts

100/38

70/21

430

1.63

476

1.80

682

2.58

80/27

465

1.76

535

2.03

822

3.11

90/32

476

1.80

585

2.21

842

3.19

gal./day m

3

/day

100/38

605

2.29

645

2.44

1078

4.08

70/21

80/27
90/32

min.

100/38

70/21
80/27

90/32

min.

100/38

70/21

263

18.5

263

18.5

265

18.6

80/27

263

18.5

263

18.5

265

18.7

90/32

263

18.5

263

18.5

265

18.6

PSIG kg/cm

2

G

100/38

264

18.6

263

18.5

267

18.8

70/21

53

3.7

54

3.8

55

3.9

80/27

54

3.8

56

3.9

56

3.9

90/32

54

3.8

57

4.0

58

4.0

PSIG kg/cm

2

G

100/38

54

3.8

57

4.0

58

4.1

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

45 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in

bold

should be used for reference only.

We reserve the right to make changes in
specifications and design without prior notice.

28

28

30

2.8

5.0

3.6

4.4
3.5

2.8

4.5

27

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

115-120/60/1

50/10

70/21

90/32

726

727
723
720
719

730
728
727

30

32
33
35

722
718
715
710

31

28
29

31

HARVEST CYCLE TIME

HEAD PRESSURE

4.0
3.4

4.4

2.6

BLSprunger

11/29/2005

2.4

TOTAL HEAT OF REJECTION FROM CONDENSER

5,700 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

APPROVED

CHECKED

WRITTEN

SUCTION PRESSURE

ENG.F-011.1.0205

Advertising
This manual is related to the following products: