Hoshizaki KM-320MAH User Manual

Page 30

Advertising
background image

30

Problem

Possible Cause

Remedy

c) Overload Protector

1. Bad contacts.

1. Check for continuity and

replace.

2. Voltage too low.

2. Increase voltage.

3. Refrigerant

overcharged or
undercharged.

3. Recharge.

4. Line valve continues

to close in freeze cycle
and overload protector
operates.

4. Check line valve’s

operation in freeze cycle
and replace.

d)Starter

1. Bad contacts.

1. Check and replace.

2. Coil winding opened. 2. Replace.

e)Start Capacitor or Run

Capacitor

1. Defective.

1. Replace.

f) Magnetic Contactor

1. Bad contacts.

1. Check for continuity and

replace.

2. Coil winding opened. 2. Replace.

g)Compressor

1. Wiring to compressor. 1. Check for loose

connection or open, and
replace.

2. Defective.

2. Replace.

3. Protector tripped.

3. Reduce temperature.

h)Controller Board

1. Defective.

1. See "II.B.5. Checking the

Controller Board."

i) Water Regulator

1. Set too high.

1. Adjust lower.

[4] Water continues to

be supplied in freeze
cycle.

a)Water Solenoid Valve

1. Diaphragm does not

close.

1. Check for water leaks with

icemaker off.

b)Controller Board

1. Defective.

1. See "II.B.5. Checking the

Controller Board."

[5] No water comes from

spray tubes. Water
pump will not start, or
freeze cycle time is
too short.

a)Water Supply Line

1. Water pressure too

low and water level in
water tank too low.

1. Check and get

recommended pressure.

b)Water Solenoid Valve

1. Dirty mesh filter or

orifice and water level
in water tank too low.

1. Clean.

c) Water System

1. Water leaks.

1. Check connections for

water leaks, and replace.

2. Clogged.

2. Clean.

3. Pump out check valve

leaking by.

3. Check assembly and

clean.