Sequence, Important – Hoshizaki KM-320MAH User Manual

Page 13

Advertising
background image

13

3. Sequence

IMPORTANT

1. Board never accepts defrost completion signal

within the first 2 minutes in defrost cycle.

2. Defrost cycle time is limited to 20 minutes even

if defrost timer does not stop counting.

4. Defrost timer stops counting.

Defrost cycle is completed and
freeze cycle starts.

1. Unit energized and control switch to "ICE"

position. Water supply cycle starts.

2. After 1 minute, defrost

cycle starts.

5. After the first 5 minutes in freeze cycle.

Ready to complete freeze cycle when float
switch circuit opens.

3. Thermistor reads 48°F (9°C).

Defrost timer starts counting.

IMPORTANT

Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.

IMPORTANT

Water valve opening is
limited to 6 minutes.

Defrost Timer

Water Valve

Water Valve

Hot Gas Valve

Defrost
Cycle

Freeze
Cycle

Pump, Fan &
Line Valve

1st Cycle

Advertising