39

7) Install a new drier.
8) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.
9) Evacuate the system and charge it with refrigerant. See the nameplate for the required

refrigerant charge.

10) Cut the leads of the solenoid allowing enough lead length to reconnect using closed

end connectors.

11) Connect the new solenoid leads.
12) Attach the solenoid to the valve body and secure it with a screw.
13) Replace the panels in their correct positions.

14) Turn on the power supply.

G. Removal and Replacement of Evaporator

IMPORTANT

Always install a new drier every time the sealed refrigeration system is opened.
Do not replace the drier until after all other repairs or replacement have been
made.

1) Turn off the power supply.
2) Remove the panels and the top insulation over the evaporator.
3) Recover the refrigerant and store it in an approved container.
4) Remove the spray tubes and the insulations at the "U" shaped notch where the

refrigeration tubings pass through the molded chassis.

5) Remove the insulation tube and disconnect the evaporator inlet tubing at the tee next to

the expansion valve.

6) Lift up the evaporator and disconnect the evaporator outlet tubing.
7) Install the new evaporator.
8) Install the new drier.
9) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

10) Evacuate the system and charge it with refrigerant. See the nameplate for the required

refrigerant charge.

11) Replace the removed parts in the reverse order of which they were removed.
12) Replace the top insulation and the panels in their correct positions.
13) Turn on the power supply.