L O C AT I O N

The merchandisers have been designed for use only in
air conditioned stores where temperature and humidity
are maintained at or below 75°F and 55% relative
humidity. DO NOT allow air conditioning, electric fans,
open doors or windows (etc.) to create air currents
around the merchandiser, as this will impair its correct
operation.

Product temperature should always be maintained at a
constant and proper temperature. This means that from
the time the product is received, through storage,
preparation and display, the temperature of the product
must be controlled to maximize life of the product.

UN-CRATING THE STAND

Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the
case from the skid. The fixture can now be lifted off the
crate skid. Lift only at base of stand!

EXTERIOR LOADING

These models have not been structurally designed to
support excessive external loading. Do not walk on
their tops; This could cause serious personal injury and
damage to the fixture.

Retighten glass along clamshell
after leveling and first time case
is brought to full operating
temperature!

GLASS BREAKAGE

MAY OCCUR!

GLASS ADJUSTMENT

During shipment, the lubricant inside the cylinders may
have settled. This settling may cause excessive or uneven
tension on the glass - to the point of breakage. To avoid
any damage, please follow these three easy steps:

1. Slowly raise and lower each glass section 6 times to

a height of 6 inches.

2. Increase the height to 12 inches, and raise and lower

the glass 6 more times.

3. Finally raise the glass to its full extension, and lower.

These steps should release any settled lubricant within
the cylinders and prevent any stress on the front glass.

LEVELING
IMPORTANT! It is imperative that cases and
supporting counters be leveled from front to
back and side to side prior to joining. A level
case is necessary to insure proper operation,
water drainage, and plexiglass alignment.

NOTE: A. To avoid removing concrete flooring, begin

lineup leveling from the highest point of the store
floor.
B. When wedges are involved in a lineup, set them
first.

Installation

All cases were tested at a level state before shipping.
When joining, use a carpenters level and shim enclosing
or supporting cabinet accordingly.

1. Make sure the cabinet you are installing the FC4H

CINNABON on is level.

2. Wire unit according to local codes.

Electrical

WIRING COLOR CODE

L1

BLACK

L2

ORANGE

L3

BLUE

NEUTRAL

WHITE

NOTE: High Leg Connection

Orange Only

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual

configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length
fluorescent lamps located within the case at the top.

The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the
rear of the case mullion.

The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
five amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedi-
cated circuit.

ELECTRICAL SERVICE RECEPTACLES
(When Applicable)

The receptacles located on the exterior of the merchan-
diser are intended for scales and lighted displays. They