Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed
electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF YOU
ARE ABSENT FOR EXTENDED TIME PERIODS. THIS
WILL PREVENT ACCIDENTAL FIREPLACE OPERATION.

Intermittent Pilot Ignition (IPI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED
.

!

!

Figure 23. Intermittent Pilot Ignition (IPI) Wiring Diagram

Optional Accessories

Optional remote control kits require that 110-120 VAC be
wired to the factory installed junction box before the fire-
place is permanently installed.

Wall Switch

Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the fire-
place to connect the wall switch to the appliance. Instead of
the supplied assembly, wire with a length of 25 ft or less and
a gauge of 20 AWG through 14 AWG is acceptable. The
wire needs a jacket with a temperature rating of 140

o

F (60

o

C)

or higher. At the appliance connect the wire to the ON/OFF
switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GR

N

OR

G

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS