Section 4: maintaining & servicing – Heat & Glo Fireplace EVEREST User Manual

Page 27

Advertising
background image

Heat & Glo • Everest • 750-900 Rev. L • 1/06

27

4

Maintaining and Servicing
Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main-
tenance will depend on use and the type of installation, you
should have a qualified service technician perform an appli-
ance check-up at the beginning of each heating season.
See the table below for specific guidelines regarding each
fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING
YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner.
Replace old ember material with new dime-size and shape
pieces of Golden Ember (DE-93) and Glowing Ember (050-
721). New ember material should be placed alternately on
top of the burner - a layer of Golden Ember, a layer of
Glowing Ember, and so on. Save the remaining ember
material and repeat this procedure at your next servicing.
For more information, see Placing Ember Material.

Cleaning Burner and Controls

Frequency: Once annually.

By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace
logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)
Frequency:
Periodically.
By: Qualified service technician.
Task: Make a visual check of the straight flame sensor rod.
Use emery cloth to carefully remove any existing white
deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns.
Make sure the flames are steady - not lifting or floating.
See Figure 28.

Checking Vent System

Frequency: Before initial use and at least annually
thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to
ensure that no debris is interfering with the flow of air. Inspect
entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As necessary
after initial cleaning.

By: Home owner.

Task: Clean as necessary, particularly after adding new ember
(flame colorant) material. Film deposits on the inside of the
glass door should be cleaned off using a household glass
cleaner. NOTE: DO NOT handle or attempt to clean the
door when it is hot and DO NOT use abrasive cleaners.

Figure 28.
Burner Flame Patterns

Advertising