Trigger commands, Resetting the standard product defaults, Menu commands – HandHeld Entertainment Document Reader 4800dr User Manual

Page 105: Using a serial trigger command (see, Terminal interfaces

Advertising
background image

4800dr Barcode Guide

10 - 3

Trigger Commands

You can activate and deactivate the document reader with serial trigger commands. First, the document reader must be put in

Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode barcode (

page 3-3

), or by sending the Manual/

Serial Menu Command (

page 10-6

). Once the document reader is in serial trigger mode, the trigger is activated and deacti-

vated by sending the following commands:

Activate: SYN T CR

Deactivate: SYN U CR
The document reader scans until a barcode has been read, until the deactivate command is sent, or until the serial time-out has

been reached (see "Read Time-Out" on page 3-3 for a description, and the serial command on

page 10-6

).

Resetting the Standard Product Defaults

If you aren’t sure what programming options are in your document reader, or you’ve changed some options and want the factory

settings restored, scan the Standard Product Default Settings barcode below.

The chart on the following pages lists the factory default settings for each of the menu commands (indicated by an asterisk (*)

on the programming pages).

Menu Commands

Note: Not all menu commands apply to all document reader models.

Selection

Setting

* Indicates default

Serial
Command

# Indicates a
numeric entry

Page

Factory Default Settings

Default

DEFALT

10-3

Terminal Interfaces

Terminal ID

*130 - USB COM Port Emulation
000 - TTL-232
124 - USB PC Keyboard
125 - USB Mac Keyboard
131 - USB HID POS

TERMID###

1-3

Standard Product Default Settings

Advertising