FAILURE
CODE

STATE OF
LED 5-4-3-2-1

TROUBLE
SHOOTING

POSSIBLE REASONS

DC fan motor fault

Fan is blocked, or the terminal is disconnected
from the PCB

Faulty 4-way valve
switching on

Coil of 4-way valve is disconnected, or faulty
outdoor PCB

Abnormal communication

between main PCB and

SPDU(or ISPM)

Communication cables broken, or not be well
connected, or faulty main PCB, or faulty SPDU(or

ISPM)

Compressor be locked

Faulty compressor or SPDU(or ISPM)

Compressor vibration too big Faulty compressor
Compressor lose position

Faulty SPDU(or ISPM)

Faulty compressor start

Faulty compressor or SPDU(or ISPM)

Faulty position checking
circuit

Faulty SPDU(or ISPM)

Compressor broken

Faulty compressor or SPDU(or ISPM)

Take off the plastic cover on the right side of the unit, you can find the LEDs near the communication terminal.
Symbol means the LED is ON, and symbol means the LED is OFF.

15

16

25

26
27
28
29

30

31

1

Faulty defrost sensor Te

Sensor disconnected, or broken, or short circuit

Faulty sensor Tao

Sensor disconnected, or broken, or short circuit

2

Faulty sensor Ts

Sensor disconnected, or broken, or short circuit

3

Faulty sensor Td

Sensor disconnected, or broken, or short circuit

4

Input overcurrent

Over current of the system, or broken of the current
sensor,or malfunction with indoor or outdoor fan
motors, or faulty PCB.

5

Abnormal communication
between indoor and outdoor
units

Wrong connection, or the wires be disconnected, or
wrong address setting of indoor units, or faulty
PCB, or faulty power supply

6

System high pressure
protection

High pressure switch is disconnected, or high
pressure switch worked, or Tc too high and faulty
outdoor fan motor when cooling, or faulty indoor
fan motors when heating, or refrigerant
overabundance

9

System low pressure
protection

Low pressure switch is disconnected, or low
pressure switch worked, or Te too low and faulty
outdoor fan motors when heating, or faulty indoor
fan motor when cooling, or refrigerant shortage

10

IPM protection

IPM over current, or short circuit, or IPM
temperature too high, or IPM input voltage too
low,or faulty SPDU(or ISPM).

11

EEPROM fault

Faulty outdoor unit PCB

12

Over hot protection of
compressor

Serious lack of refrigerant of the system, or the
ambient temperature too high, or PMVs be
blocked

13

Over hot protection of SPDU
(or ISPM)

Ambient tempreatrue too high, or outdoor fan be
blocked, or bad air circulation of outdoor unit

14

Faulty sensor Tc

Sensor disconnected, or broken, or short circuit

17

Faulty sensor Toci

Sensor disconnected, or broken, or short circuit

21

Low voltage protection

VDC<194V, too low voltage from power source

23
24

High voltage protection

VDC>400V, too high voltage from power source