Uh68odk tent heater 4-2, Vent fan carb htr ignition comb blr – Hunter Fan UH68ODK User Manual

Page 28

Advertising
background image

UH68ODK Tent Heater

4-2

1
2

J6

CONN-H2

ZCC

1

2

3

6

5

4

U5

MOC3031

R10

180

M2

M1

G

U8

1
2

J5

CONN-H2

1
2

J3

CONN-H2

1
2

J4

CONN-H2

R15

180

R1

20K

R4

500K

VENT FAN

CARB HTR

IGNITION

COMB BLR

VI

1

VO

3

GND

2

U1

L4805
MOUSER # 511-L4805CV

R16

5.0

C6

0.1uF

C4

100uF

D6

TVS-18V

V+

1

GP5/OSC1/CLK

2

GP4/OSC2/AN3

3

GP3/MCLR

4

GND

8

GP0/AN0

7

GP1/AN1/Vref

6

GP2/T0CLK/AN2/I

5

U3

PIC12C67X

nc

8

nc

7

nc

6

nc

5

nc

1

V+

2

V-

3

nc

4

U2

TMP17

S1

FLAME SWITCH

N.O. 125F (i.e. it closes at 125F)

D11

LED

R18

5.6K

R20

150

D8

1N4001

D7

1N4001

SW1

SW-SP-ON-OFF-ON

C7

0.1uF

R8

38

C8

0.01uF

R9

1K

R2

500K

D4

TVS

C1

330uF 63WV

C5

100uF

D5

4.7V

C3

22uF

D9

LED

R19

150

D10

LED

R22

150

ZCC

1

2

3

6

5

4

U4

MOC3031

R11

180

M2

M1

G

U7

R14

180

R6

38

C9

0.01uF

R7

1K

ZCC

1

2

3

6

5

4

U6

MOC3031

R12

180

M2

M1

G

U9

R13

180

R3

38

C10

0.01uF

R5

1K

J9

Cir.Brk2

J8

Cir.Brk1

D3

MOV

D1

MOV

D2

MOV

1
2
3
4
5
6

J12

CONN-H6

1
2
3
4
5
6

J10

CONN-H6

D12

LED

R21

150

1

4

8

5

6

7

TR1

24 V @ 1.5A

1
2

J11

CONN-H2

1
2

J15

CONN-H2

1

4

8

5

6

7

TR2

8V @ 300mA

+

-

AC2

AC1

BR2

BRIDGE
1.5 A 100V

+

-

AC2

AC1

BR1

BRIDGE

4 A 600V

1
2

J1

FUEL PUMP

1
2

J2

FUEL SOL.

1
2
3

J7

CONN-H3

1
2

J14

OVERHEAT SW

1
2
3
4

J13

CONN-H4

D13

1N4004

R17

10K

R23

10K

C11

0.1uF

C12

0.1uF

C2

22uF

Note on Blink Codes

Only the ignition fault will stop heater operation. The other flash codes will be displayed
but the heater will continue to operate.









Troubleshooting Procedures

Electrical Schematic