background image

UH68 ODK/ODH Tent Heater

2-2

Table 3. Blink Codes
Number of Blinks Problem

1

Low voltage at AC input (< 100 VAC)

2

Reverse polarity at AC input

3

High voltage (>130 VAC)

4 Not

used

5

PC Board over temp

6 Not

used

7 Not

used

8

Ignition Fault Lockout

Note: Only the Ignition fault lockout will shut down the heater. Any other code will flash the red
led, but still allow the heater to operate normally.
























Table 4.
Key

Connection / Fitting

Function

1

Power Receptacle

Connection for power cable

2

Remote Control Receptacle

Connection for remote control

3

Fuel Inlet

QD fitting for fuel supply

4

Fuel Overflow

QD fitting for fuel overflow




1

2

3

4