Problem:
Excessive noise.

Solution:
1. Check the Water Tank to make sure

it is properly seated on the Power Pack.

2. Check the Water Tank to make sure

there are no bubbles when the Water
Tank is full and running. If there are bub-
bles, turn the unit OFF until the bubbling
stops. When the bubbling has stopped,
set the unit to the desired speed.

3. Remove and clean the Pump Cap

and Funnel Pump. Refer to the section
on CLEANING THE HUMIDIFIER AND
THE WATER TANK.

Problem:
Humidifi er not working.

Solution:
1. Make sure the Power Knob is not set

to OFF.

2. Adjust the humidity level using the

Power Knob and the Humidistat Controls.
Once the room reaches the set humidity
level, the humidifi er will turn OFF; this is
normal.

3. Make sure the Power Pack and Water

Tank are both fully seated in the three
tabs on the Upper Reservoir.

4. Make sure the Atomizer is facing the

proper direction.

Problem:
Humidifi er will not turn on.

Solution:
1. Check the three posts on the top

surface of the Atomizer are properly en-
gaged. The side of the Atomizer with three
short posts should be facing upward.

2. Make sure the Water Tank is properly

seated on the Power Pack.

3. Check the humidity levels on the display.

If the ambient room humidity is equal to
or higher than the set level, the unit will
not turn on.

Problem:
Mineral build-up on the Water Tank or Upper

Reservoir.

Solution:
1. Refer to the section on CLEANING

THE HUMIDIFIER AND THE WATER
TANK.

Problem:
Humidity output and water usage

decreased.

Solution:
1. Make sure the Atomizer is positioned

correctly, with the side with three posts
facing upward.

2. Check the Humidistat Setting and

Power Knob to make sure they are set
to the desired humidity level.

3. Check the Water Tank to make sure

there are no bubbles when the Water
Tank is full and running. If there are bub-
bles, turn the unit OFF until the bubbling
stops. When the bubbling has stopped,
set the unit to the desired speed.

4. Clean any components that have

mineral build-up. Refer to the section
on CLEANING THE HUMIDIFIER AND
THE WATER TANK.