HRV200PLUS INSTALLATION INSTRUCTIONS

b. Attaching the CoolVent™ to the Fresh Air Fireplace Flue Collar

1) Secure a CoolVent™ appliance connector to the CoolVent™ insulated flexible pipe per the manufacturer’s instructions.
2) Apply a generous bead (1/2 inch) of RTV high temperature silicone to the flue collar and attach the appliance adaptor.

c. Assembling the Vent Pipe Sections

1) When it is necessary to connect two or more lengths of CoolVent™ insulated flexible pipe in a vent run, use a universal

connector at each joint.

2) Always support CoolVent™ insulated flexible pipe every three feet.

WARNING!

The maximum TOTAL EXHAUST vent run is measured from the flue collar of the Fresh Air Fire-

place, through the HRV, to the outside termination. DO NOT EXCEED MAXIMUM VENTING LENGTHS!

3. Fresh Air Fireplace Exhaust

- Stale air/combustion products from the FAF to the HRV

Duct Materials: CoolVent™ Flexible Pipe (1” air clearance to combustible materials)

Firestops, Hangers and Accessories as Required

a. Fresh Air Fireplace Exhaust Guidelines

1) FAF must be vented with CoolVent™ flexible insulated vent pipe, maintaining 1” (25.4mm) clearance to combustible

surfaces.

WARNING!

When vent sections exceed three feet (.9m) in length ensure minimum clearances are

maintained. Structural support must be provided to reduce off-center loading. Follow

manufacturer installation instructions..

Note: 1” (25.4mm) air clearance to combustibles must be maintained
when using CoolVent™ in this portion of the venting system.

2) The total combined length of the CoolVent™ run for the Fireplace Exhaust and the HRV Exhaust must not exceed the

maximum lengths shown in the following table:

3) Direction of flow may include any combination horizontal, vertical up or vertical down.

4) The entire vent run must be contained within an area which will not experience temperatures below 40°F.