Model OFE/OFG/OEA/OGA-341, 342



3-9. FILTERING OF

6.

Rinse the frypot as follows:

SHORTENING

a.

Close the drain valve.

(Continued)

b. Position return line over empty frypot. Figure 3-8.

c.

Move the pump switch to the pump position.

d.

Fill the frypot 1/3 full, then turn off pump.

e.

Wash down and scrub the sides of the frypot

with the brushes.

f.

After the sides and bottom are cleaned, open the

drain

valve.


7.

Close drain valve and pump all of the shortening out of

the filter drain pan and back into the frypot.


Figure 3-8


IF SHORTENING FLOW IS SLOW FROM THE

FAUCET, IT’S POSSIBLE THAT THE FILTER

CONNECTION AT THE UNION ON THE

FILTER TUBE IS NOT TIGHTENED

PROPERLY. IF SO, TURN OFF THE PUMP AND

WEAR ROTECTIVE GLOVES OR CLOTH

WHEN TIGHTENING THE UNION. THIS

UNION WILL BE HOT. SEVERE BURNS

COULD

RESULT.


8.

When the pump is pumping air only, move the pump

switch from on to off.



9.

Check the level of the shortening in the frypot. Add

fresh shortening if necessary, until it reaches the top

level indicator line on the rear wall of the frypot.














406

3-15