Model OFE/OFG/OEA/OGA-341, 342



The Computron 1000 controls are available on both split

electronic controls frypot and full frypot fryers. The following is a

brief description of the operating procedures for fryers with these

controls.

1.

Be sure the drain valve is in the closed position.


2.

Place basket support inside of frypot.

3. Make sure frypot is filled with shortening to the proper
level.

4.

Display shows “OFF” until power switch is turned to the ON

position. Display now shows the cook time and the unit

automatically goes into the Melt Cycle until the

shortening

temperature

reaches

230

°F (110°C). The

control then automatically exits the Melt Cycle.

The OFG-320 series open fryer has several safety devices
which shuts-down the gas supply when they are activated.
The above procedures should be followed to restart the open
fryer and if the shut down is repeated, a qualified technician
should be notified.

The Melt Cycle may be bypassed, if desired, by pressing

and holding for 3 seconds.

Do not bypass the Melt Cycle unless enough shortening

on gas fryers and elements on electric fryers. If Melt

Cycle is bypassed before all burner tubes or elements

are covered, excessive smoking of the shortening, or a

fire

will

result.

5.

Once out of the Melt Cycle, the shortening is heated

until lights and the cook time is displayed.


Thoroughly stir shortening to stabilize the temperature

throughout

the

frypots.

6.

Before

loading

product into the baskets, lower baskets

into the hot shortening to keep the product from

sticking

to

the

baskets.

7.

Once the shortening temperature has stabilized at the

setpoint temperature, lower the basket with product into

the frypot.

408

3-7

3-4. C1000 OPERATIONS

AND PROCEDURES