SKU 96325

for technical questions, please call 1-800-444-3353.

HePa filter (25) on HePa

frame (16) with HePa cover

(26)

HePa frame (16)

HePa filter (25) on HePa

frame (16)

The HEPA Filter should be rinsed with clean water periodically and allowed to
air-dry completely before being used again. Do not use compressed air to speed
up the drying process.
The HEPA Filter should be removed before vacuuming up liquids to prevent it from
becoming fouled and obstructing air-flow.

vacuuming

Before each use, inspect the general condition of the Vacuum. Check for loose

screws, misalignment or binding of moving parts, cracked or broken parts, damaged
electrical wiring, and any other condition that may affect its safe operation. If abnormal
noise or vibration occurs during use, turn the Vacuum off promptly and have the problem
corrected before further use.

using the vacuum for liquids:

danger! flammability Hazard: This product should never be used to vacuum up haz-

ardous liquids, such as fuel, oil, or acid.

Unlatch and remove the Vacuum Assembly. Make sure the Float (15) is in place
and moves freely.

Remove the HEPA Filter and the Dust Bag, replace the HEPA Cover, reattach the
Vacuum Assembly, and connect the Hose Connection to the lower inlet.

WARNING. Make sure the Off Button (2) is depressed before plugging the

Vacuum into a standard 120V outlet.

Attach the Utility Brush to the end of the Hose and use the attachment to vacuum
up the water.

When the Vacuum has reached it’s maximum capacity, the Float (15) will automati-
cally shut the unit off and the Indicator Light (4) will illuminate to indicate that the
unit is full.