Model SCD-6/8

2-2

203

2-4. BLOWER REPLACEMENT

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove the side panel closest to the controls.

3. Cut the 3 wires to the blower motor (Figure 2-2).

Figure 2-2

4. Using a Phillips head screwdriver, remove the mounting

screws (Figure 2-3).

Figure 2-3

5. Cut seal around the plastic housing and pull blower from unit

(Figure 2-4).

6. Mount new blower, sealing the blower housing with high

temperature sealant.

7. Matching the wire colors, connect the wires of new blower with

those cut in step 3, using wire nuts or wire splicers.

Figure 2-4

8. Secure wires to keep out of components.

9. Replace side panel and restore electrical power.