Chart – Heat & Glo Fireplace 8000TRD User Manual

Page 14

Advertising
background image

14

HORIZONTAL VENTING

Kit No.

H Max. Run

DVK-01D
DVK-01TRD

24" (610 mm)

Figure 10. Corner Installation

NOTE: 8000TRD model is tested and approved
to use 45° elbows in corner installations.
However, 90° elbows will result in better per-
formance.

45-DEGREE

ELBOW

90-DEGREE

ELBOWS

H

3. Match the amount of vertical you have in the sys-

tem with the chart to find the appropriate position
to set the Flue Restrictor.

1 2 3 4 5

SETTINGS

1 2 3 4 5

Figure 9

- CHART -

Vertical

Top Vent

NG

Top Vent

LP

Rear Vent

NG

Rear Vent

LP

4'

1-1

No

Restrictor

No

Restrictor

No

Restrictor

8'

2-2

1-2

1-1

No

Restrictor

15'

3-3

3-2

2-2

1-2

20'

3-4

3-3

3-3

2-3

25'

3-4

3-3

3-3

2-3

30'

4-4

3-4

3-4

3-3

35'

4-4

3-4

3-4

3-3

40'

5-4

4-4

4-4

3-4

4. Center the Flue Restrictor on vent and secure in

place by using two self-tapping screws (see Fig-
ure 9).

5. Reinstall the Exhaust Shield.