Venting with two (2) 90° elbows – Heat & Glo Fireplace 8000TRD User Manual

Page 16

Advertising
background image

16

Figure 13. Venting with Two 90° Elbows

VENTING WITH TWO (2)

90° ELBOWS

V

H

H + H

1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

5´ MAX. (1.52m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

10´ MAX. (3.1m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

15´ MAX. (4.65m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

20´ MAX. (6.2m)

V+H+H

1

= 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H

1

= 20´ MAX. (6.2m)

Figure 14. Venting with Two 90° Elbows

VENTING WITH TWO (2) 90

o

ELBOWS

V FT.

H + H

1

(FT.)

1' MIN.

(305mm)

5´ MAX. (1.52m)

2' MIN.

(610mm)

10´ MAX. (3.1m)

3' MIN.

(914mm)

15´ MAX. (4.65m)

4' MIN.

(1.22m)

20´ MAX. (6.2m)

V+H+H

1

= 40' MAX.(12.4m) H+H

1

= 20´ MAX. (6.2m)

V+V

1

+H

= 40' MAX.(12.4m)

Advertising