Heat & Glo Fireplace 8000TRD User Manual

Page 29

Advertising
background image

29

Intermittent Pilot Ignition (IPI) Wiring

3 Volt Transformer

This appliance comes with a 3 volt transformer found in the
manual bag. Plug the transformer leads to the green con-
trol module (see Figure 39). Then plug the transformer into
the side outlet on the junction box.

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED
.

Operation using Battery Power

This fireplace has an optional battery operation. The sys-
tem is fully functional with the use of two “D” size batteries
without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in
order to conserve battery life. In the case of a loss of power,

!

!

Figure 39. Intermittent Pilot Ignition (IPI) Wiring Diagram

NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts.
120 VAC is required at junction box unless equipped with battery back-up.

simply connect red and black wire leads to activate battery
power (connect red to red, black to black). The fireplace
can be used as necessary. Once power (110 VAC) is re-
stored, disconnect red and black wire leads to extend bat-
tery life.

Optional Accessories

Optional remote control kits require that 110-120 VAC be
wired to the factory installed junction box before the fire-
place is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.

NEUTRAL

GROUND

REMOTE

CONTROL

HOT

LOW VOLTAGE

SEE NOTE 1

ON/OFF

WALL SWITCH

VALVE

BROWN

BROWN

RED

ORANGE

GREEN

BLACK

OPTIONAL

BATTERY
BACK-UP

BLACK (IGNITOR)

BLACK (SENSOR)

BLACK

GROUND TO

FIREPLACE

CHASSIS

PILOT ASSEMBLY

AND VALVE ASSEMBLY

MUST BE GROUNDED

(COMMON GROUND

WITH FIREPLACE

CHASSIS)

SPARK TO

PILOT IGNITOR

IGNITOR

MODULE

3V

120 VAC

JUNCTION BOX

T

R

A

N

S

F

O

R

M

E

R

3

V

FAN

TRANSFORMER OUTLET

PLUG-IN

3V TRANSFORMER

FLAME SPARKER /

SENSOR

LOW VOLTAGE

SEE NOTE 1

OPTIONAL

BATTERY
BACK-UP

IGNITION

MODULE

(3V)

ON/OFF

SWITCH

REM

TRANSFORMER

3V