Installer guide, Getting started – Heat & Glo Fireplace 8000TV-OAK User Manual

Page 16

Advertising
background image

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08

16

4

4

Getting Started

A. Typical Appliance System

NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual

CEILING FIRESTOP
ON FLOOR OF ATTIC
(SECTION 8.B)

VERTICAL TERMINATION CAP

(SECTION 4.D)

VENT PIPE PENETRATES ROOF
PREFERABLY WITHOUT AFFECTING
ROOF RAFTERS (SECTIONS 8.B and 8.C)

FRAMING HEADED OFF
IN CEILING JOISTS
(SECTION 8.B)

GAS LINE
SECTION

MANTEL AND MANTEL LEG
(SECTION 5.D)

SURROUND

HEARTH EXTENSION

VENT PIPE (SECTIONS 6 and 7)

OPTIONAL

WALL SWITCH

ATTIC INSULATION SHIELD (NOT SHOWN) MUST
BE USED HERE TO KEEP INSULATION AWAY
FROM VENT PIPE IF ATTIC IS INSULATED (SECTION 10.D)

STORM COLLAR
(SECTION 4.D)

NON-COMBUSTIBLE ROOF FLASHING
MAINTAINS MINIMUM CLEARANCE
AROUND PIPE (SECTIONS 4.D)

FRAMING/HEADER
(SECTION 5)

Figure 4.1 Typical System

Installer Guide