E. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.

Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram

Figure 12.3 Standing Pilot Ignition Wiring Diagram

WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on
3 volts. 120 VAC is required at junction box unless equipped with
battery back-up.

RED

IGNITION

MODULE 3 VAC

GREEN

ORG

WHITE

INTERMITTENT

PILOT IGNITOR

VALVE

TRANSFORMER 3V

GROUND TO FIREPLACE CHASSIS

BLACK

BROWN

IGNITION MODULE 3 VAC

INTERMITTENT
PILOT IGNITOR

THERMOSTAT WIRE ASSEMBLY

GROUND TO FIREPLACE CHASSIS

TRANSFORMER

3 VAC

ORG

TEMP SENSOR

BATTERY PACK

ORG

GREEN

VALVE

BROWN

ORG

WHITE

TEMP SENSOR

BATTERY PACK

RED

BLACK

PLUG-IN

PLUG-IN

JUMPER W

IRE

T

O

BROWN

REMOTE RECEIVER

S

I

THERMOCOUPLE

WHITE

WHITE

TEMP SENSOR

REMOTE

RECEIVER

VALVE

RED

PIEZO

VALVE

RED

TEMP SENSOR

PILOT

PILOT

THERMOCOUPLE

THERMOSTAT WIRE ASSEMBLY

Advertising