Optional Accessories

Installation of the electrical junction box is required if using
a blower or remote. To install:

Uncoil the junction box cord and feed the end of the
cord through the hole on the right side of the base pan.

Turn the junction box at a 45-degree angle and insert it
into the sidewall of the base pan.

Turn junction box so it is flush with sidewall and screw
into place with the screw provided in the manual bag.

Gently pull the end of the cord until cord is tight. Place
the strain relief on the cord and then place it into hole on
base pan.

Plug the cord into a convenient outlet. An electrician
may install an outlet box inside the fireplace. Place the
outlet in the lower, back corner of the fireplace supplied.
Make sure fan doesn’t touch back wall.

Fan Option (FB-IN & FB-Grand ONLY)

On units already installed removal of decorative front, sur-
round and gas insert is required.

• Detach flexible liner from back of unit.

• Remove the four screws on the coverplate (see Figure 11).

• Bend up the tabs on the base pan (see Figure 10).

• Place the blower in between the bend up tabs.

• Install and wire the blower per instruction shipped with
the fan.

• The ground wire of the fan can clip on the side of the
base pan.

• Reinstall the cover plate back on the unit. Make sure
the fan does not make contact with the back wall.

Figure 9.
Junction box installation

JUNCTION

BOX

SIDEWALL

FEED PLUG

THROUGH HOLE

INSERT STRAIN RELIEF

AROUND CORD IN THIS END

FROM OUTSIDE OF UNIT

SCREW

PROVIDED

Figure 10. Fan Wiring Diagram

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
105

0

C RATED WIRE.

WARNING: MUST USE THE CORD SUPPLIED
WITH THE J-BOX.

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

FAN

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

JUNCTION

BOX

GROUND WIRE

(ATTACH TO ANY

METAL SURFACE)