3-7. PROGRAMMING

The duration of time the temperatures (in 9 and 10

(Continued)

above) must remain at before the alarms will sound.
Press 11 times and the digital display shows the time at
which the high and low temperatures (no. 9 and 10 above) must
remain before the alarm sounds.

The factory setting is 20 minutes, but can be changed to a
maximum setting of 60 minutes or a minimum of 10 minutes
by pressing .

This means that the temperature must remain at a too high or
too low temperature for 20 minutes before an alarm sounds.

International Only. A Frigiprobe temperature at which
the compressor turns off in a Chilling Cycle, to prevent
freezing of the product.
Press

12 times and the digital

display shows the temperature at which a sensor in the
Frigiprobe turns off the compressor during a Probe Mode.
This prevents the outer surfaces of the product from freezing;
however, the cooling time will be greatly increased.

The factory setting is 39ºF (4ºC), but can be changed to a
maximum setting of 122ºF (50ºC) or a minimum of 32ºF
(0ºC) by pressing .

Do not change this setting lower than the setting used in param-
eter 22, (next page).

This function will only activate when the factory setting is
changed to above 40ºF (4ºC). England must have a setting
of 3ºC (37ºF).

Re-initialize the controls to factory settings. Press the
13 times and the digital display shows “dEF”, at which
time is pressed and the unit shuts down. Re-initialization
is now complete.

After re-initialization, the controls default back to factory
settings. The temperature will be in Celsius and the values in
steps 12, 16, and 18 of this section need to checked to be
accurate for the country in which the unit is installed.