Henny Penny BCF-24/65/110 User Manual

Page 8

Advertising
background image

Model BCF-24/65/110, BCM-110

3-5. CLEANING

Daily:
1.

Make sure the power switch is in the off position.

2.

Remove all product from the unit.

3.

Remove the racks and pans from the unit and clean with
soap and water at a sink.

4.

Clean all surfaces, including the Frigiprobe, with a soft cloth,
soap and water. Do not use abrasive cleaners!

Do not use steel wool, other abrasive cleaners or
cleaners/sanitizers containing chlorine, bromine, iodine
or ammonia chemicals, as these will deteriorate the
stainless steel, and glass material, and shorten the life of
the unit.

Do not use a water jet (pressure sprayer) to clean the
unit, or component failure could result.

5.

Clean around the electronic controls and the door seal with
a soft, damp cloth.

6.

The unit is now ready for operation.

Henny Penny has the following cleaners available:

Foaming Degreaser - Part no. 12226
Food Service Sanitizer - Part no. 12059
Stainless Steel Cleaner/Polish - Part no. 12060

See your local distributor for details.

Weekly:
Once a week, the evaporator coils need cleaning to ensure the unit
runs efficiently and to remove corrosive build-up on the coils.

To avoid personal injury, move the power switch to OFF
and unplug the power cord from the wall, or disconnect
main circuit breaker.

Wear protective gloves to reduce the risk of cuts from
the coil.

1.

Remove the racks and pans from the unit

2.

Using a flat-head screwdriver, remove the screws securing the
evaporator cover and swing the cover out to access the coils.