Henny Penny BCF-24/65/110 User Manual

Page 14

Advertising
background image

Model BCF-24/65/110, BCM-110

3-7. PROGRAMMING
(Continued)

Frigiprobe temperature for when the buzzer sounds at
the start of a cycle.
Press 17 times, and the tempera-
ture that the buzzer sounds when the product

has reached the

“danger zone” temperature, and must be cooled to a “safe”
temperature within the recommended time, is shown in the
display.

The factory setting is 140ºF (60ºC), but can be changed to a
maximum setting of 176ºF (80ºC) and a minimum setting of
122ºF (50ºC) by using .

The settings for the U.S.A. must be 140ºF (60ºC) and for
England, 158ºF (70ºC).

Intermediate Printer Setting. Press 18 times and a
printing temperature, between the starting temperature and the
ending temperature, can be set. Along with printing the tem-
perature information at the end of a cycle, the printer can be set
to capture temperature information in the middle of the cycle.

The factory setting is -40ºF (-40ºC), but can be changed to a
maximum setting of 176ºF (80ºC) and a minimum setting of
40ºF (-40ºC) by using .

A setting lower than parameter deactivates this function.

Selecting Fahrenheit or Celsius. Press
19 times and ºF or ºC shows in the display. Press
to change from ºF to ºC, or vice versa.
(Once is pressed, the display goes blank.)

3-14

1105

Displayed Step

23

30

24

22

Advertising