Electrical hookup, Model krzh, Wiring numbers and colors – Hill Phoenix KRZH User Manual

Page 14

Advertising
background image

10

ELECTRICAL HOOKUP

When connecting to the junction box

on the bottom left side of the case, field
wiring should exit the junction box from the
right hand side, furthest away from case
wiring, increasing room inside for wire con-
necting.

DEFROST HEATERS, 208/240 VOLTS

L1

L2

RED

BLUE

EVAPORATOR FANS, 120 VOLT

ANTI-CONDENSATE HEATERS, 120 VOLT

WIRE NUMBER

COMPONENT

COLOR CODING

BLACK

TEMPERATURE CONTROL, 120 VOLT

LIGHTS, 120 VOLT

DEFROST TERMINATION CONTROL, 120 VOLT

WHITE

3

4

11

12

13

14

19

20

21

WHITE

BLACK

WHITE

BLACK

YELLOW

YELLOW

PURPLE

ORANGE

23

WIRING NUMBERS AND COLORS

EQUIPMENT GROUNDING CONDUCTOR

GREEN

-

BLACK

WHITE

DOOR & FRAME ANTI-COND. HEATERS, 120 VOLT

15

16

Electrical hookups are made to a

junction box located at the top, left of the
case. For case-to-case wiring, run “green-
field”, or other conduit, between junction
boxes.

MODEL

KRZH

44 5/8 in

[113.3 cm]

34 1/4 in

[87.0 cm]

7 13/16 in

[19.9 cm]

ELECTRICAL

(TOP OF CASE)

20 3/4 in

[52.7 cm]

**

42 7/16 in

[107.8 cm]

44 5/8 in

[113.3 cm]

1 1/2 in [3.8 cm]

{END}

FRONT OF CASE

60 in. [152.4 cm.] {2-DOOR}
90 in. [228.6 cm.] {3-DOOR}

120 in. [304.8 cm.] {4-DOOR}
150 in. [381.0 cm.] {5-DOOR}

NOTES:

* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

C

L

TOP ACCESS
HATCH

ELECTRICAL ACCESS HOLE
(Drilled through rear of case)

Advertising