Maintenance – Hill Phoenix KRZH User Manual

Page 25

Advertising
background image

21

USE

AND

MAINTENANCE

CASE CLEANING

Case is designed to facilitate cleaning. There is no

mechanical or electrical controls in the product area to
hamper routine cleaning. All surfaces pitch to a deep-
drawn drain trough that angles toward the front and center
of case where the 2” waste outlet is located for easy
access.

The coil and fan plenum are located outside the

product area to keep food fluids from entering, diminish
downtime, and reduce shrink. If cleaning is required,
make certain fan plenum is properly closed after cleaning
to avoid air leaks.

POSITIVE DRAIN OFF

COIL CLEANING

CLEAN HONEYCOMB

HONEYCOMB

REAR

HONEYCOMB

RETAINER

SCREW

LOOSEN SCREWS IN
REAR HONEYCOMB
RETAINER AND
TWIST HONEYCOMB
OUT

LIFT UP TOP
HATCH TO EASILY
ACCESS COIL
AND PLENUM

TOP HATCH

CLEANING PROCEDURES

• A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency, and

avoid the corrosive action of food fluids on metal parts that are left on for long periods of time. We recommend cleaning once
a week.

• To avoid shock hazard, be sure all electrical power is turned off before cleaning. In some installations, more than one

disconnect switch may have to be turned off to completely de-energize the case.

• Check waste outlet to insure it is not clogged before starting the cleaning process and avoid introducing water faster than the

case drain can carry it away.

• Avoid spraying cleaning solutions directly on fans or electrical connections.

• Provide a temporary separator between those cases which are being cleaned and those which are not.

• Allow cases to be turned off long enough to clean any frost or ice from coil and flue areas.

• Remove and clean discharge honeycomb. You may need to use spray detergent and a soft, long bristle brush.

• Use mild detergent and warm water. When necessary, water and baking soda solution will help remove case odors. Avoid

abrasive scouring powders or pads.

• Remove front panels and clean underneath the case with a broom and a long handled mop. Instructions for removing the

front panels can be found on page 6 of this manual.

• Use warm water and a disinfecting cleaning solution when cleaning underneath the cases.

• When cleaning antifog doors please refer to Appendix A, on page 26, for more details.

Advertising