Manning AirAlert-96d Gas Monitor

19073 AIRALERT96D 05/2006 Prelim REVC Copyright © 2006 Honeywell Analytics. All Rights Reserved.

3

1

Introduction

Warning

To ensure your personal safety, read “Safety
Information” (below) before you use the controller.

The AirAlert

TM

96d system sets new standards in gas

detection and in the measurement of environmental
parameters.

Acting as the nerve center of a modular gas detection
network, the AirAlert

TM

96d provides continuous

monitoring of up to 96 connected units on three
distinct channels.

The AirAlert

TM

96d provides a full array of displays. At

a glance, it is possible to determine the status of the
entire network. Field modifications are straight-
forward. A menu driven program allows for minor
fine-tuning of the sequence of operation all the way
to the reconfiguration of the entire network.

Since no two projects are alike, the AirAlert

TM

96d is

designed to be highly customized. Combined with
ease of installation, this unit represents the most
affordable gas monitoring solution for institutional,
commercial and light industrial applications.

For more advanced applications, the AirAlert

TM

96d

controller provides datalogging capacity within a
cast aluminum enclosure. The perfect solution for
even the most complex of industrial applications.

A

Safety Information — Read First

Use the controller only as specified in this manual,
otherwise the protection provided by the controller
may be impaired.

Read the

Warnings and Cautions on the following

pages before using the controller.

Note: This instrument contains a lithium battery.
Do not mix with the solid waste stream. Spent
batteries should be disposed of by a qualified
recycler or hazardous materials handler.

Warning: To prevent ignition of flammable
or combustible atmospheres, disconnect
power before servicing.

Do not use the controller if it is damaged.
Before you use the controller, inspect the
case.

If the controller is damaged or something is
missing, contact Honeywell Analytics
immediately.

To avoid possible damage to the controller:

Do not expose the controller to electrical
shock and/or severe continuous mechanical
shock.

Do not attempt to disassemble, adjust, or
service the controller unless instructions for
that procedure are contained in the manual
and/or that part is listed as a replacement
part. Use only Manning replacement parts.

The controller Warranty could be voided if customer
personnel or third parties damage the controller
during repair attempts.

B

Getting Started

Intended Use

The AirAlert

TM

96d controller will provide around the

clock monitoring of the gas detection network.
Moreover, a log of all the sensors concentrations and
alarms will be created for analysis with the data-
logger option. Also, the grouping/zoning capabilities
will result in energy cost savings.

Figure 1. AirAlert

TM

96d

Caution

To avoid possible personal injury:

Warning: Substitution of components may
impair intrinsic safety.

Manning AirAlert 96d

Warn

Alarm

High Alarm

Fault

Power

Enter

ESC

Silence

TX

RX