33

How to Attain Better Images

Black Balance Adjustment

Adjust black balance to provide proper color tone at a dark part of video image. In the following cases, be sure to carry

out black balance adjustment.

When using the camera first after purchasing it.

When using the camera after it has been unused for a long time.

Wen the camera operating environment is changed (e.g., when the ambient temperature varies significantly).

Under normal condition, it is not required to make black balance adjustment at power-on.

1. In the Direct mode, hold the ABB button pressed for about 2 seconds for automatic black balance adjustment. With

MESSAGE RTN:ON, AUTO BLACK appears. At the end of successful adjustment AUTO BLACK:OK appears.

(Notes)

1) Where the lens having the auto iris function is used, the iris is closed automatically during adjustment.

Sometimes occurs when adjusted with the lens iris in the manual mode (lens iris switch set to M). Open

the iris for better exposure.

2) In combinational use with the manual iris lens or microscope, a full-black screen image is provided from

the CCD image sensor during adjustment. When picturing after adjustment, a white screen image appears

momentarily. This phenomenon is not a symptom of trouble, however.

3) In case that the manual iris lens is used, do not attempt auto black balance adjustment while taking an

image of subject having extremely high luminance such as the sun. This may deteriorate black balance

accuracy.

2. If black balance adjustment cannot be made, any one of the following messages will appear. Take a proper procedure

according to the error message, and then try black balance adjustment again.

Error message

Procedure

AUTO BLACK:NG

CHANGE TO CAM

TRY AGAIN

Turn off the color bar.

AUTO BLACK:NG

IRIS NOT CLOSE

TRY AGAIN

Close the lens iris.

Avoid taking an image of subject having high luminance such as the sun, or decrease

illumination on the microscope.

AUTO BLACK:NG

???

TRY AGAIN

Carry out ABB again. If this message appears in repeated attempts, it is necessary to

inspect the inside of the camera. In this case, notify your local Hitachi Denshi sales

agent or Hitachi Denshi service office