Installation of Molded Brick Panel

A. Install Hearth Molded Brick Panel

• Place hearth panel into the fireplace.

B. Install Back Molded Brick Panel/Traditional

• Remove screen rods

• Remove the smokeshield

• Refer to Figure 11.1.

• Set the grate brackets in place, 26.5 in. (673 mm) center

to center.

• Install the back panel. Center from side to side.

• Install two Z-brackets in the mortar lines across the top.

Tighten these and all previously installed brackets.

C. Install Side Molded Brick Panel/Traditional

• If a gas line is to be installed, remove the knockouts in

the inner firebox and in the outer shell on the side of

your choice. Refer to dimension drawings for location of

knockouts and Section 13.A. for gas provisions.

• Install side panel, tapered edge to the front. Align the front

edge with the front of the column (or butted to the surround

if installed).

• Install two Z-brackets in the mortar lines across the top.

Tighten these and all previously installed brackets.

• Install second side panel following the steps above.

• Replace the smokeshield.

Figure 11.1 Traditional Molded Brick Panel

LH Traditional Refractory

Back Traditional Refractory

Hearth

Refractory Clip

Heatilator • Birmingham BIR42-B • 4059-681C • 9/12