Non-combustible Sealant

After completing the framing and applying the facing mate-

rials over the framing, a bead of non-combustible sealant

must be used to close off any gaps at the top and sides

between the fireplace and hearth.

Non-combustible Sealant

Figure 12.7 Flush Hearth Extension

Flush Hearth Extension Framing

• Fireplace must be recessed 3 3/4 in. (95.3 mm) below the

finished floor.

• Refer to Figures 12.7 and 12.8.

Figure 12.8 Flush Hearth Extension Side View

Figure 12.6 Place Non-combustible Sealant

Non-combustible Finishing Material

Protective Metal

Hearth Strip

30 in. Min.

Hearth Extension

1 in. (25.4 mm)

Micore and

1/2 in. (13 mm)

Durock

Finished

Floor

Bottom of

Fireplace Opening

Note: The bottom of the fireplace opening

is 3-3/4 in. (95.3mm) above the bottom of

the fireplace. Finished hearth must NOT

extend above this level.

Heatilator • Birmingham BIR42-B • 4059-681C• 9/12