INTRODUCTION

Hatco FR2 Hydro-Heater Food Rethermalizers/Hot
Food Table Heaters are designed to supply
temperature-controlled water to a holding vessel
(sink or tank) located above the heater. Water
flows by natural convection from the holding vessel
directly into a tubular water chamber with heating
elements uniquely wrapped on the outside
of the flow tube. The heating elements do
not come in direct contact with the water
eliminating sediment and lime buildup
on the element, resulting in longer life. The heated
water flows upward and returns to the holding
vessel. A special electronic controller maintains
the setpoint temperature assuring a responsive
and efficient operation.

The unit electrical and plumbing connections
are factory-assembled and ready for installation.

This manual provides the installation, safety
and operating instructions for the Hydro-Heater

Food Rethermalizers/Hot Food Table Heaters.
We recommend all installation, operating and safety
instructions appearing in this manual be read prior
to installation or operation of your Hatco Hydro-
Heater. Safety instructions that appear in this
manual after a warning symbol and the words
WARNING or CAUTION printed in bold face
are very important. WARNING means there
is the possibility of serious injury or death
to yourself or others. CAUTION means there
is the possibility of minor or moderate injury.
CAUTION without the symbol signifies
the possibility of equipment or property
damage only.

Hatco Hydro-Heaters are a product of extensive
research and field testing. The materials used
were selected for maximum durability, attractive
appearance and optimum performance. Every
unit is thoroughly inspected and tested prior
to shipment.

CONTENTS

Important Owner Information...............................i

Introduction ...........................................................i

Important Safety Instructions .............................1

Model Descriptions ..............................................2

All Models........................................................2

FR2 Models.....................................................2

Units with Built-In Temperature Control ..........2

Units with Remote Temperature Control .........2

Specifications.......................................................3

Electrical Rating Chart - FR2 Models .............3

Sizing Information ...........................................4

Dimensions......................................................4

Electrical..........................................................4

Installation ............................................................5

Plumbing .........................................................5

Auto-Fill ...........................................................6

Operation ..............................................................7

Start-Up Procedures........................................7

Minutes to Heat Table .....................................8

Maintenance .........................................................9

General............................................................9

Daily ................................................................9

Weekly...........................................................10

Deliming Instructions.....................................10

Hatco Limited Warranty.....................................12

Authorized Parts Distributors ............Back Cover

IMPORTANT OWNER INFORMATION

Record the model number, serial number
(identification plate located on the lower right hand
side, front corner of the unit), voltage and purchase
date of your Hydro-Heater in the spaces below.
Please have this information available when calling
Hatco for service assistance.

Model No. ________________________________

Serial No. ________________________________

Voltage __________________________________

Date of Purchase __________________________

Form No. FR2M-0604

Business 8:00 a.m. to 5:00 p.m.

Hours: Central

Standard

Time

(Summer Hours: June to September -

8:00 a.m. to 5:00 p.m. C.D.T.

Monday through Thursday

8:00 a.m. to 2:30 p.m. C.D.T. Friday)

Telephone: (800) 558-0607; (414) 671-6350

Fax:

(800) 690-2966 (Parts & Service)

(414) 671-3976 (International)

Additional information can be found by visiting our

web site at www.hatcocorp.com

24-Hour 7-Day Parts & Service