SECTION 4. TROUBLESHOOTING

4-1. TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

The evaporator is iced-up

• The door was closed

• Open the door when following

after a De-icing Cycle

the de-icing procedure

• Evaporator temperature at end

• Increase the setting of Step 8 in

of De-icing Cycle too low

Programming Section

• Maximum time of De-icing Cycle

• Increase the setting of Step 7 in

too short

Programming Section

Too much water on

• The unit has been shut down

• Start a De-icing Cycle

evaporator fins

without a De-icing Cycle

Slow to decrease

• Temperature of room too high

• Ventilate the room

in temperature (decline in
performance)

• Back of unit too close to

• Change the location of the

the wall

unit

Slow to decrease

• Condenser obstructed by dirt

• Clean the condenser

in temperature (decline in
performance)

Evaporator iced up

• Perform a De-icing Cycle

Display temperature does

• In Probe Mode, the display

• Normal

not match the actual inlet air

shows the product temperature

temperature (No alarm)

All indicator lights off and

• Check electrical supply

• Plug unit into receptacle, or

ON/OFF switch will not

reset wall circuit breaker

operate

• Fuse of control board blown

• Change the fuse