Testing and adjustments, Maximum range maximum coverage angle* (top view), Least sensitive most sensitive – Heath Zenith Motion Sensing Diecast Metal Lantern 9600LED series User Manual

Page 5

Advertising
background image

5

598-1338-03

testing anD aDjustments

1.

turn on the circuit breaker and light switch.

Note: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned on
wait 1

1

/

2

minutes.

2. Set:

ON-TIME switch to TEST

SENSITIVITY dial to Midway

3. Walk through the coverage area noting where you

are when the lights turn on. In TEST mode, light
will stay on for 5 seconds after sensing motion and
then turn off.

4. Adjust the SENSITIVITY to increase or decrease

the range as needed. Too much sensitivity may
cause false triggering due to heat sources in the
coverage area (see Adjustment of Coverage Area
or Troubleshooting section).

5. Set the amount of ON-TIME you want the light to

stay on after motion is detected (5 or 10 minutes)
or...

Set the ON-TIME to the DUSK-to-DAWN setting
if you want the light to stay on all night, every
night. The photocell will turn the light off during
the day.

Maximum Range

Maximum

Coverage Angle*

(Top View)

TEST

5 10 DUSK

MINUTES TO DAWN

+

SEN

30 ft.

(9.1 m)

6 ft.

(1.8 m)

180°

Photocell

Least Sensitive

Most Sensitive

The sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coverage area.

Sensor

Motion

Motion

Advertising