Automatic ignition/operation – Harman Stove Company HARMAN P68 User Manual

Page 14

Advertising
background image

14

P68 Pellet Stove

3-90-00688R24_06/13

autoMatic ignition/oPeration

The P68 is a fully automatic stove that features two operating

modes;

stove temperature Mode and room temperature

Mode. In Stove Temperature Mode, you select a burn rate

and the stove will remain at the same burn rate regardless

of the room temperature.
In the Room Temperature Mode the stove constantly monitors

the temperature in the room and adjusts the size of the fire

and the heat output of the stove so that the room is kept at

a constant temperature. Room mode, in the AUTO position,

has the added advantage of turning the stove off if no heat

is required and turning the stove on again when the room

temperature drops below your desired room temperature.
room temperature Mode

Most consumers use the stove in the Room Temperature

Mode because it is the easiest and most efficient method

of keeping the room at a given temperature. In the Room

Temperature Mode, the Room Sensing Probe constantly

monitors room temperature. As the weather changes outside

and your home needs varying amounts of heat to be at a

desired temperature, the stove will automatically increase

size and heat output of the fire so that a constant even

temperature is maintained. If the weather warms up and no

heat is required the stove will gradually shut down. When the

house cools down the stove will automatically bring the room

temperature to the precise temperature you desire.
In the Room Temperature Mode you can select either

auto

or Manual modes for the igniter using the igniter toggle

switch. When the toggle switch is in the Auto position the

igniter located inside the burn pot is ready to automatically

light the fire when required. When the toggle switch set to the

Manual position the stove can be lit manually with either a gel

or a wax type fire starter. (see lighting instructions on page

18.) With the igniter toggle switch set in the Manual position

the stove will automatically adjust heat output, but the stove

will not automatically shut down if no heat is required. Instead

it will go to its lowest setting and remain there. The Manual

position on the igniter toggle switch lets you light the stove

manually, should the igniter fail for any reason. Secondly if

you are using the Harman battery back up system the Manual

setting will prevent the stove from turning off and on during

a power failure, which would drain the back up battery, and

possibly cause damage to the back-up or the stove.
In the Room Temperature Mode, the distribution blower speed

can be increased or decreased by adjusting the Room Temp/

Off/Stove Temp dial between L and H. As output of the stove

increases, the speed of the blower will increase automatically

to insure that more heat is transferred out into the room. The

distribution blower will shut off as the room reaches the set

temperature, this will prevent overheating of the room.

room temperature Mode: This setting, see above, will produce

a room temperature of 70 degrees with the distribution blower at

medium speed.

room temperature Mode

KeeP aPPliance doors closed While in

oPeration. Maintain all seals in good condition.